2-35 KV crosslinked PE cable
2-35 kV Crosslinked Polyethylene (XLPE) CABLES | |
Standard | CNS 2655-C2047 |
Rated voltage | 2 kV |
Construction | Conductor: annealed strand copper |
Conductor shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Insulation: crosslinked polyethylene (XLPE) | |
Insulation shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Shielding: annealed copper tape | |
Filler: PP yarn, ramie yarn, plastics or other filler material | |
Tape: fabric, plastics or other taping material | |
Sheath: poly(vinyl chloride) (PVC) | |
No. of cores | Single core and 3 cores |
Nominal sectional area | Single core: 2 - 500 mm2 |
3 cores: 2 - 325 mm2 | |
Standard | CNS 2655-C2047 |
Rated voltage | 5kV |
Construction | Conductor: annealed strand copper |
Conductor shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Insulation: crosslinked polyethylene (XLPE) | |
Insulation shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Shielding: annealed copper tape | |
Filler: PP yarn, ramie yarn, plastics or other filler material | |
Tape: fabric, plastics or other taping material | |
Sheath: poly(vinyl chloride) (PVC) | |
No. of cores | Single core and 3 cores |
Nominal sectional area | Single: 8 - 1000 m㎡ |
3 cores: 8 - 325 m㎡ | |
Standard | CNS 2655-C2047 |
Rated voltage | 8 kV |
Construction | Conductor: annealed strand copper |
Conductor shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Insulation: crosslinked polyethylene (XLPE) | |
Insulation shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Shielding: annealed copper tape | |
Filler: PP yarn, ramie yarn, plastics or other filler material | |
Tape: fabric, plastics or other taping material | |
Sheath: poly(vinyl chloride) (PVC) | |
No. of cores | Single core and 3 cores |
Nominal sectional area | Single core: 14 - 1000 m㎡ |
3 cores: 14 - 325 m㎡ | |
Standard | CNS 2655-C2047 |
Rated voltage | 15 kV |
Construction | Conductor: annealed strand copper |
Conductor shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Insulation: crosslinked polyethylene (XLPE) | |
Insulation shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Shielding: annealed copper tape | |
Filler: PP yarn, ramie yarn, plastics or other filler material | |
Tape: fabric, plastics or other taping material | |
Sheath: poly(vinyl chloride) (PVC) | |
No. of cores | Single core and 3 cores |
Nominal sectional area | Single core: 38 - 1000 m㎡ |
3 cores: 38 - 325 m㎡ | |
Standard | CNS 2655-C2047 |
Rated voltage | 25 kV |
Construction | Conductor: annealed strand copper |
Conductor shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Insulation: crosslinked polyethylene (XLPE) | |
Insulation shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Shielding: annealed copper tape | |
Filler: PP yarn, ramie yarn, plastics or other filler material | |
Tape: fabric, plastics or other taping material | |
Sheath: poly(vinyl chloride) (PVC) | |
No. of cores | Single core and 3 cores |
Nominal sectional area | Single core: 38 - 500 m㎡ |
3 cores: 38 - 325 m㎡ | |
Standard | JIS C3606 |
Rated voltage | 3.3 kV |
Construction | Conductor: annealed strand copper |
Conductor shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Insulation: crosslinked polyethylene (XLPE) | |
Shielding: annealed copper tape | |
Filler: PP yarn, ramie yarn, plastics or other filler material | |
Tape: fabric, plastics or other taping material | |
Sheath: poly(vinyl chloride) (PVC) or polyethylene (PE) | |
No. of cores | Single core and 3 cores |
Nominal sectional area | Single core: 8 - 1000 m㎡ |
3 cores: 8 - 325 m㎡ | |
Standard | JIS C3606 |
Rated voltage | 6.6 kV |
Construction | Conductor: annealed strand copper |
Conductor shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Insulation: crosslinked polyethylene (XLPE) | |
Insulation shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Shielding: annealed copper tape | |
Filler: PP yarn, ramie yarn, plastics or other filler material | |
Tape: fabric, plastics or other taping material | |
Sheath: poly(vinyl chloride) (PVC) or polyethylene (PE) | |
No. of cores | Single core and 3 cores |
Nominal sectional area | Single core: 8 - 1000 m㎡ |
3 cores: 8 - 325 m㎡ | |
Standard | JIS C3606 |
Rated voltage | 6.6 kV |
Construction | Conductor: annealed strand copper |
Conductor shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Insulation: crosslinked polyethylene (XLPE) | |
Insulation shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Shielding: annealed copper tape | |
Filler: PP yarn, ramie yarn, plastics or other filler material | |
Tape: fabric, plastics or other taping material | |
Sheath: poly(vinyl chloride) (PVC) or polyethylene (PE) | |
No. of cores | Single core and 3 cores |
Nominal sectional area | Single core: 8 - 1000 m㎡ |
3 cores: 8 - 325 m㎡ | |
Standard | TPC-A043 |
Rated voltage | 15 kV |
Construction | Conductor: annealed strand copper |
Conductor shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Insulation: crosslinked polyethylene (XLPE) | |
Insulation shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Shielding: tinned copper wire | |
Sheath: poly(vinyl chloride) (PVC) | |
No. of cores | Single core |
Nominal sectional area | 2 AWG (MCM) - 1000 AWG (MCM) |
Standard | TPC-A043 |
Rated voltage | 25 kV |
Construction | Conductor: annealed strand copper |
Conductor shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Insulation: crosslinked polyethylene (XLPE) | |
Insulation shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Shielding: tinned copper wire | |
Sheath: poly(vinyl chloride) (PVC) | |
No. of cores | Single core |
Nominal sectional area | 1 AWG (MCM) - 1000 AWG (MCM) |
Standard | ICEA S-66-524 |
Rated voltage | 2001- 5000 V |
Construction | Conductor: annealed strand copper |
Conductor shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Insulation: crosslinked polyethylene (XLPE) | |
Insulation shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Shielding: annealed copper tape | |
Filler: PP yarn, ramie yarn, plastics or other filler material | |
Tape: fabric, plastics or other taping material | |
Sheath: poly(vinyl chloride) (PVC) | |
No. of cores | Single core and 3 cores |
Nominal sectional area | Single core: 8 AWG (MCM) - 1000 AWG (MCM) |
3 cores: 8 AWG (MCM) - 500 AWG (MCM) | |
Standard | ICEA S-66-524 |
Rated voltage | 5001- 8000 V |
Construction | Conductor: annealed strand copper |
Conductor shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Insulation: crosslinked polyethylene (XLPE) | |
Insulation shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Shielding: annealed copper tape | |
Filler: PP yarn, ramie yarn, plastics or other filler material | |
Tape: fabric, plastics or other taping material | |
Sheath: poly(vinyl chloride) (PVC) | |
No. of cores | Single core and 3 cores |
Nominal sectional area | Single core: 6 AWG (MCM) - 1000 AWG (MCM) |
3 cores: 6 AWG (MCM) - 500 AWG (MCM) | |
Standard | ICEA S-66-524 |
Rated voltage | 8001 - 15000 V |
Construction | Conductor: annealed strand copper |
Conductor shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Insulation: crosslinked polyethylene (XLPE) | |
Insulation shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Shielding: annealed copper tape | |
Filler: PP yarn, ramie yarn, plastics or other filler material | |
Tape: fabric, plastics or other taping material | |
Sheath: poly(vinyl chloride) (PVC) | |
No. of cores | Single core and 3 cores |
Nominal sectional area | Single core (insulation level 100%): 4 - 1000 AWG (MCM) |
Single core (insulation level 133%): 1 - 1000 AWG (MCM) | |
3 cores (insulation level 100%): 4- 500 AWG (MCM) | |
3 cores (insulation level 133%): 1- 500 AWG (MCM) | |
Standard | ICEA S-66-524 |
Rated voltage | 28001 - 35000 V |
Construction | Conductor: annealed strand copper |
Conductor shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Insulation: crosslinked polyethylene (XLPE) | |
Insulation shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Shielding: annealed copper tape | |
Filler: PP yarn, ramie yarn, plastics or other filler material | |
Tape: fabric, plastics or other taping material | |
Sheath: poly(vinyl chloride) (PVC) | |
No. of cores | Single core and 3 cores |
Nominal sectional area | Single core (insulation level 100%): 1 - 1000 AWG (MCM) |
Single core (insulation level 133%): 1 - 1000 AWG (MCM) | |
3 cores (insulation level 100%): 1 - 500 AWG (MCM) | |
3 cores (insulation level 133%): 1 - 500 AWG (MCM) | |
Standard | ICEA S-66-524 |
Rated voltage | 15001 - 25000 V |
Construction | Conductor: annealed strand copper |
Conductor shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Insulation: crosslinked polyethylene (XLPE) | |
Insulation shielding: semi-conductive crosslinked polyethylene or semi-conductive fabric tape | |
Shielding: annealed copper tape | |
Filler: PP yarn, ramie yarn, plastics or other filler material | |
Tape: fabric, plastics or other taping material | |
Sheath: poly(vinyl chloride) (PVC) | |
No. of cores | Single core and 3 cores |
Nominal sectional area | Single core (insulation level 100%): 1 - 1000 AWG (MCM) |
3 cores (insulation level 100%): 1 - 500 AWG (MCM) |
Copyright © 2020 大山電線電纜股份有限公司